What is Nonstandard Fault Diagnosis and How Do We Deal With It?

What is it?

Wondering what a non-standard fault diagnosis is? If you are not a maintenance person, this may sound alien to you, but for maintenance people out there, it may be a piece of common knowledge. To give you a brief context, this kind of fault can easily be prevented by the thorough configuration and setup of your Fluke tool. Yes, that’s right, nonstandard fault diagnosis can stem from the assembly of your Fluke tool itself.

So before you go blaming the machine, see if you’ve got everything inputted in your Fluke device. Then again, aside from the setup itself, there are also some other underlying issues on why your Fluke tool is tagging it as a nonstandard fault diagnosis.

The three main causes of nonstandard fault diagnosis

With the use of Fluke tools, no doubt you can spot issues within your machines in a jiffy! For this one, we strongly recommend the use of the Fluke 810. Vibration Testers are one of the most recommended tools to spot machine faults. Not only is it highly effective in the field, but it can give you accurate diagnoses and solutions.

One of the most wonderful functions of this Fluke tool is its ability to detect, locate, and assess the severity of issues within equipment and rotating parts. May it be bearing condition, misalignment, imbalance, or looseness, one thing is for sure, it can be seen and resolved with the use of the Fluke 810 Vibration tester. In line with this, it can also tell nonstandard faults. Here are the three main causes…

1. Incorrect or incomplete setup. For this to work, you need to accurately input all the data of your machine while setting up the Fluke 810 Vibration Tester. One of the common faults of why you’re getting a nonstandard fault diagnosis is you’ve not put all the information of the machine you’re testing. So take note, it’s important for you to process everything while setting up your vibration tester.

2. Incorrect or insufficient data collection. Again, incorrect inputting of data plays a big hand in this. Technically, this happens when the minimum data collection requirements were not met. Moreover, the running speed of the machine (which was not accurately entered) can also be the cause of this.

3. Vibration condition other than one of the four standard faults. Yes, you can still have a nonstandard fault diagnosis other than detecting the four standard faults. Ideally, The Fluke 810 recognizes these readings. However, we will get to that in a little bit.

How to deal with nonstandard fault diagnosis

If you find yourself having a nonstandard fault diagnosis whilst doing a normal testing procedure, the next thing you should do is to have another test. See if the result stays the same or if it changed. If the results change, then it might just be the effects of having data collection errors or vibration events. However, if you do get another nonstandard fault diagnosis, then it might be high time to undergo another process. Here is how you will do it…

  • You might have to tinker with your Fluke tool. Specifically check if information about the driver, transmission, and driven component has been entered (or other relevant data). In addition, also take note of the component types. Was the AC motor accurately described like the DC? How about the screw compressor? It might have been entered as a piston compressor.

Technically, these are the things you have to double-check once you have a second reading of a nonstandard fault diagnosis.

  • Data quality and quantity are enough to achieve an accurate diagnosis. Again, complete information is necessary when you’re working with the Fluke 810 Vibration Tester. A good practice (or something to keep in mind) is never to set up or test partial drivetrains.
  • Double-check if the vibration data was collected. See if the location and orientation of the components are the same as the ones on the setup diagram in the Fluke 810.

Consider these other fault conditions…

In such a time that you’ve inputted all information but are still getting the same nonstandard fault diagnosis result, then you might consider these other faults that are not brought up by your Fluke 810 device setup. According to an official Fluke source, these are the probable causes…

Electrical

Electrical switching fault in a variable frequency drive

Problems with Motor components (stator, winding, commutator, brush)

Motor lamination looseness

Motor air gap problem

Line phase voltage imbalance

Non-bearing mechanical element wear or defect

Pump component (vane, timing gear, impeller, piston, idler shaft, rotor) wear or clearance problemsMotor cooling fan blade damage

Gearbox input shaft pinion problem

First gear mesh problem or wear

Fan wheel wobble

Fan dirt buildup or blade clearance problem

Sheave problems

Drive belt irregularity

Coupling wear

Compressor components (rotor thread, piston/valve, impeller, lobe) wear

Flow related

Pump cavitation or air ingestion

Fan airflow disturbance

Compressor gas pulsation Structural

Structural vibration or resonance

Motor or pump mounting flexibility

Motor foundation flexibility or resonance

Foundation weakness or resonance

Foundation vibration

Fan mounting transverse flexibility

Other

Overloaded accelerometer

Oil whirl

Oil whip 

Resolve these failures using Fluke Tools!

Hey, you made it to the bottom! Are you currently looking for the best-performing test tools in the market to run daily maintenance checks on your rotating machines? You’re in luck cause Presidium PH is an authorized distributor of Fluke test tools in the Philippines. Prevent these faults from penetrating your rotating machine by using the best test tools there are!

If you want to know more about Fluke tools and their functions, visit our website for more info! This is a one-stop shop for the best test tools within Metro Manila.

Leave a Comment

Your email address will not be published. Required fields are marked *

DISCLAIMER

All products shown in this webpage are representations only of the products wished to be promoted. It may vary color and size in actual appearance. Specifications of the use of the Fluke products can be found in the brochures that accompany each product and/or those found in the official website of Fluke.
The prices of the Fluke products are those indicated herein and they are true and correct as of the time they were published. Prices may change without prior notice.
Fluke products are designed for very specific and special purpose(s) and shall not be used for any purpose other than those expressly set forth in applicable Fluke product documentation. The registered trademark, marks, logos of Fluke products including patent, copyright, and other propriety rights belong to them exclusively.
Warranty of the products sold in this website are subject to certain and specific conditions which must be identified and known to the buyers prior to the purchase.
All rights reserved.

RETURN & REPLACEMENT POLICY

HOW TO PURCHASE: To place an order, you will be required to fill out the order form legitimately and press the “Add to cart / check out” button to submit your order. After this, you will receive an e-mail from us acknowledging that we have received your order.
AVAILABILITY OF PRODUCT: All orders for products are subject to availability.
SHIPPING: Customers will be responsible for paying for their shipping costs for deliveries. Shipping costs are nonrefundable. Orders placed on Friday will be processed and shipped the following Monday.
NO REFUND POLICY
PRODUCT QUALITY CONCERNS: Product that is unusable due to reasons related to Product quality arising out of the manufacturing of the Product.
PRODUCT DEATH ON ARRIVAL (DOA): Product that purchased is defective once arrived.
REPLACEMENT POLICY: We only replace product if they are defective or damaged. In circumstances where you consider that a product is defective, you should promptly contact us at • +632 84590167 • +632 82570795 • +632 82515165 or email us at info@presidium.ph with details of the product and the defect.
RETURN POLICY:
  • You must notify us thru email or contact us if you wish to return or replacement of the product.
  • You have 7 calendar days to return an item from the date you received it.
  • To be eligible for a return, your item must be unused and in the same condition that you received it.
  • Product must be in original packaging, including instruction manuals and all accessories. Product must be unused and in original condition.
  • Item needs to have the receipt or proof of purchase.
  • Your item would be subject for checking of our Technical support before replacement.
CONTACT: If you have any queries regarding these terms and conditions, please contact us at • +632 84590167 • +632 82570795 • +632 82515165 email us at info@presidium.ph